Flares that light — and stay lit.
Igniter repair, flame-out troubleshooting, and burner management on waste-gas flare stacks and utility flares across the Permian Basin. Operating from Odessa, TX.
A flare that won't light is a compliance problem and a safety problem at the same time. We service the ignition and burner management side of waste-gas flare stacks and utility flares — pilots, igniters, flame proving, and the controller logic that ties it together. If it's nuisance-tripping, flaming out, or failing to prove flame, we find the root cause instead of swapping parts until it stops.
What you're paying for.
No surprise line items. Here's exactly what's in scope.
- Flare igniter and pilot troubleshooting and replacement
- Flame-out and nuisance-lockout root-cause diagnosis
- Burner management system install and repair for flare stacks
- Flame proving via thermocouple, ionization (flame rod), or both
- Spark, HEI, and glow-plug ignition system service
- Wiring rework — bad terminations are the #1 cause of intermittent flame-outs
- Pre-inspection flare audits before TCEQ or RRC visits
Our process.
Call
Tell us the flare type and what it's doing — won't light, flames out, or won't prove flame. We quote rough hours over the phone.
Diagnose
Tech reads the alarm history and checks the ignition and proving chain before touching a part. Most flame-outs trace to one bad component.
Fix
Most igniter and proving issues are a same-day job. Larger jobs get a written quote before parts are ordered.
Document
Photos, before/after readings, and a clean PDF report in your inbox the same day via ReliableTrack.
Common questions.
Why does my flare keep flaming out or nuisance-tripping?
+
The most common causes are a failing flame rod or thermocouple, a fouled igniter, or a bad wiring termination that drops the proving signal. We read the alarm history first and trace it to the actual cause rather than swapping parts.
Do you install burner management on flare stacks?
+
Yes. We install and commission BMS on waste-gas and utility flares — including our Wi-Fi-enabled ROS BMS, which carries a flare application profile — and we service every major BMS brand.
How fast can you respond to a flare that won't light?
+
Same-day within ~75 miles of Odessa, and emergency callouts run 24/7. Call (432) 227-4106.
Can you get my flare ready for a TCEQ or RRC inspection?
+
Yes. Pre-inspection flare audits are a common request — we document deficiencies, prioritize by severity, and quote remediation so you walk into the inspection ready.